Air Bending Force Chart

Celebrating over 50 years in Australian Manufacturing.

Air Bending Chart for Mild steel Rm=450N/mm2

Die opening V

4

6

7

8

10

12

14

16

18

20

25

32

40

50

63

80

100

125

160

200

Minimum bend length bmin

2.8

4

5

5.5

7

8.5

10

11

13.5

14

18

22

28

35

45

55

71

89

113

Bending radius r

0.7

1

11

1.3

1.6

2

2.3

2.6

3

3.3

4.0

5.0

6.5

8

10

13

16

20

26

Thickness

0,5mm

40

30

0,6mm

60

40

40

40

0,8mm

70

70

50

40

1,0mm

110

100

80

70

1,2mm

140

120

100

80

70

60

1,5mm

170

150

130

110

90

80

2,0mm

220

190

170

150

130

110

2,5mm

280

250

220

180

140

3,0mm

340

300

240

190

150

3,5mm

330

260

200

160

130

4,0mm

430

340

270

210

170

4,5mm

440

340

270

210

5,0mm

520

420

330

260

210

6,0mm

750

600

480

380

300

240

7,0mm

520

410

330

260

8,0mm

850

680

530

430

9,0mm

670

540

430

10mm

850

670

530

420

12mm

960

780

600

550

15mm

950

750

Get a Quote